Type NHX
single-stage volute casing pump mechanical seal for hot water application
Q max: 1400 m³/h [616 g.p.m.]**
H max: 220 m [722 ft]**
operating pressure: 40 bar [580 psi]*
temperature: 220° C [428° F]*


Type NHX is designed for use in medium and large hot water systems.

It is a single-stage volute casing pump, with an axial suction flange and axial centerline mounted discharge flange pointing vertically upwards. The design of the DICKOW hot water circulation pump takes into account many years of experience in the hot water sector and allows for high operational reliability.

The DICKOW patented cooling and degassing system ensures moderate temperatures in the sleeve bearing area and guarantees a stable liquid film in the mechanical seal gap.

The pump is self-venting and does not require any external or water cooling. Personnel-intensive intervention from the outside is not required. High antifriction bearing temperatures are prevented even under extreme load conditions. Lowest life cycle costs by efficient hydraulics and low maintenance requirements

  • chemistry
  • petrochemistry
  • offshore
  • ship technology / marine
  • industrial heating systems / heat carrier
  • renewable energy / environmental engineering
Q max: 1400 m³/h [616 g.p.m.]**
H max: 220 m [722 ft]**
operating pressure: 40 bar [580 psi]*
temperature: 220° C [428° F]*
max rotational speed: 3500 rpm
gasket/mechanical seal: mechanical seal
installation: horizontal
self-priming: no
bearing: rolling bearing, plain bearing
lubrication: grease
materials: spheroidal graphite iron / cast steel
standards: DIN EN ISO 2858, ISO 5199
explosion protection: category 2 / zone 1
brochure (de): Download
brochure (en): Download
sectional view (de): Download
sectional view (en): Download


* higher pressures and temperatures on request
** depending on size and speed